Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Ortho Sci., Orthod. sci. pract ; 16(64): 82-89, 2023. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1551916

RESUMO

Resumo OBJETIVO: Avaliar a resistência ao cisalhamento e o Índice de Remanescente Adesivo (IRA) de bráquetes metálicos colados com três diferentes fotopolimerizadores LED de alta potência, quando comparados ao LED convencional. MATERIAIS E MÉTODOS: 80 incisivos bovinos foram divididos aleatoriamente em 4 grupos (n=20), nos quais foram realizadas colagens dos bráquetes utilizando-se os seguintes LEDs de alta potência por 3s: Grupo 1 ­ LEDX ­ T 2400, Orthometric; Grupo 2 ­ Flashmax P4 PRO Ortho, Rock Moutain Orthodontics; Grupo 3 ­ VALO CORDLESS, Ultradent e Grupo 4 ­ LED convencional por 40s (controle) POLY-WIRELESS, Kavo. O teste de resistência ao cisalhamento foi realizado utilizando-se uma máquina de ensaio universal (AME-2kN, Oswaldo Filizola, São Paulo, Brasil) com velocidade de 0,5mm/min e célula de carga de 50N. A determinação da diferença estatística entre os grupos em relação ao cisalhamento foi realizada usando-se a análise de variância (ANOVA). Para avaliação do IRA, foi aplicado o teste Kruskal-Wallis. RESULTADOS: O grupo 2 apresentou resistência ao cisalhamento significativamente superior aos demais LEDs de alta potência e foi similar ao LED convencional. Em relação ao IRA, houve diferença estatisticamente significante entre os grupos e o único que não diferiu do grupo controle foi o 2, enquanto os demais LEDs de alta potência (Grupos 1 e 3) apresentaram mais falhas adesivas entre a resina e o esmalte. CONCLUSÃO: Houve diferença entre os três tipos de fotopolimerizadores LED de terceira geração, sendo que maior resistência ao cisalhamento e menos falhas adesivas foram observadas no LED que apresentou maior potência (AU)


Abstract OBJECTIVE: To evaluate shear strength and Adhesive Remnant Index (ARI) of metallic brackets bonded to three types of high-power LED light curing, when compared to conventional LED. MATERIALS AND METHODS: 80 bovine incisors were divided into 4 groups (n = 20), in which brackets were bonded using the following high-power LEDs for 3s: Group 1 ­ LEDX ­ T 2400, Orthometric; Group 2 ­ Flashmax P4 PRO Ortho, Rock Mountain Orthodontics; Group 3 ­ VALO CORDLESS, Ultradent; and Group 4 ­ conventional LED for 40s (control) POLY-WIRELESS, Kavo. The shear strength test was performed using a universal test machine (AME-2kN, Oswaldo Filizola, São Paulo, Brasil) with 0.5 mm/min speed and 50N load cell. The determination of statistical difference between the groups in relation to shear strength was performed using analysis of variance (ANOVA). The Kruskal-Wallis test was used to assess the IRA. RESULTS: Group 2 showed shear strength significantly higher than other high-power LEDs and was similar to conventional LED. Regarding ARI, there was a statistically significant difference between the groups and the only one that did not differ from the control group was 2, while the other high-power LEDs (Groups 1 and 3) had more adhesive failures between the resin and the enamel. CONCLUSION: There was a difference between the three types of third generation LED light curing agents, with greater shear strength and less adhesive failures observed in the LED that presented higher power. (AU)


Assuntos
Braquetes Ortodônticos , Resistência ao Cisalhamento , Cura Luminosa de Adesivos Dentários
2.
Rev. odontol. UNESP (Online) ; 51: e20210058, 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1377170

RESUMO

Introduction: Endodontically treated teeth are usually affected by extensive structure loss requiring the use of intraradicular posts to provide retention and restoration. Objective: An in vitro assessment was performed on the bonding of glass fiber posts to the root dentin. Material and method: Ninety (n = 10) single bovine roots were used in a 3 x 3 x 3 factorial study with subdivided plots: post customization varying the presence and type of resin (without customization, conventional resin, and Bulk Fill resin), light-curing device (Valo, Radii-Cal, Rainbow), and root third (cervical, middle, and apical). Result: For the customization factor, Tukey's test (5%) showed the superiority of the Bulk Fill (8.16 MPa) and Z350 (7.40 MPa) groups compared to the control group (4.92 MPa), without differing from each other. All light-curing devices differed, showing the superiority of Valo (9.36 MPa), Radii (6.96 MPa) as an intermediate, and the inferiority of Rainbow (4.17 MPa). The cervical root third (7.81 MPa) was superior, the apical third was inferior (5.80 MPa), and the middle third (6.88 MPa) was an intermediate without differing from the others. Conclusion: The customization of glass fiber posts increases the bond strength to the root dentin, regardless of the resin used. There was a compromise in the apical third and when using light-curing devices with lower light intensity.


Introdução: Dentes com extensa perda de estrutura podem comprometer a retenção das restaurações ao remanescente dental, onde pinos intraradiculares são indicados. Objetivo: Avaliou-se in vitro a união de pinos de fibra de vidro à dentina radicular em função de diferentes modos de reanatomização, fotopolimerizadores e regionalização radicular. Material e método: Noventa (n=10) raízes bovinas uniradiculares foram usadas num estudo fatorial 3 x 3 x 3 com parcelas subdivididas: Reanatomização do pino, variando a presença e tipo de resina (Sem reanatomização, Resina Convencional e Resina Bulkfill); Fotopolimerizador (Valo, Radii-cal, Rainbow); e Terço radicular (cervical, médio e apical). Resultado: O teste de Tukey (5%) evidenciou para o Fator Reanatomização superioridade dos grupos BulkFill (8.16MPa) e Z350 (7.40MPa) ao grupo Controle (4.92MPa), sem diferirem entre si. Todos os fotopolimerizadores diferiram entre si, com superioridade de Valo (9.36MPa), Radii (6.96MPa) intermediário, e inferioridade de Raiwbow (4.17MPa). O terço radicular cervical (7.81MPa) foi superior e o apical inferior (5.80MPa), com o terço médio (6.88MPa) intermediário e sem diferir dos demais. Conclusão: Conclui-se que a reanatomização de pinos de fibra de vidro aumenta a resistência de união à dentina radicular, independentemente da resina utilizada, havendo prejuízo no terço apical e quando são empregados fotopolimerizadores com menor intensidade luminosa.


Assuntos
Técnicas In Vitro , Bovinos , Técnica para Retentor Intrarradicular , Cimentos de Resina , Dentina , Cura Luminosa de Adesivos Dentários , Fotoiniciadores Dentários
3.
Braz. dent. sci ; 24(4): 1-9, 2021. tab, ilus, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1337615

RESUMO

Objective: The objective of this study was to characterize and correlate the absorption spectra of three photoinitiators [camphorquinone (CQ), diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) and phenylbis (2,4,6-trimethylbenzoyl)-phosphine oxide (BAPO)], using second or third-generation light curing units (LCU), and to evaluate the degree of conversion and the physical properties of an experimental resin adhesive. Material and methods: Second-generation (Radii-cal® and Emitter D®) and third-generation (Valo® Cordless and Bluephase N®) LCU were assessed regarding spectrum and irradiance rate of emitted light. Also, the photoinitiators (CQ, TPO and BAPO) were characterized by a light absorption spectrum assessed by UV-Vis spectroscopy, degree of conversion and yellowing effect. Statistical analyzes considered two-way ANOVA and post-hoc Tukey test. Results: BAPO presented higher reactivity compared to TPO. Regarding degree of conversion of the photoinitiators activated by different light-curing units, the Emitter D® device promoted a high degree of conversion. BAPO presented the highest yellowing effect values. Conclusions: The emission and absorption characteristics of the photoinitiators were different. The polymerization reaction activated by the second-generation light-curing unit was reduced when using an experimental resin with photoinitiator TPO, and the third-generation light-curing unit showed a higher polymerization potential regardless of the photoinitiator. (AU)


Objetivo: Caracterizar e correlacionar os espectros de absorção de três fotoiniciadores [canforoquinona (CQ), difenil 2,4,6-trimetilbenzil óxido de fosfina (TPO) e óxido de di (2,4,6-trimetilbenzil) difenil fosfina (BAPO)], com unidades de fotoativação (LCU) de segunda ou terceira geração, e avaliar o grau de conversão e as propriedades físicas de um adesivo experimental. Material e métodos: LCU de segunda geração (Radii-cal® e Emitter D®) e terceira geração (Valo® Cordless e Bluephase N®) foram avaliadas quanto ao espectro e taxa de irradiância da luz emitida. Além disso, os fotoiniciadores (CQ, TPO e BAPO) foram caracterizados por um espectro de absorção de luz avaliado por espectroscopia UV-Vis, avaliado o grau de conversão dos adesivos e efeito de amarelamento. A análise estatística empregada foi ANOVA duas vias e teste post-hoc de Tukey. Resultados: BAPO apresentou maior reatividade comparado ao TPO. Em relação ao grau de conversão dos fotoiniciadores ativados por diferentes aparelhos fotopolimerizadores, o dispositivo Emitter D® promoveu um alto grau de conversão. BAPO apresentou os maiores valores de efeito de amarelamento. Conclusões: As características de emissão e absorção dos fotoiniciadores foram diferentes. A reação de polimerização ativada pelas unidades de fotopolimerização de segunda geração foi reduzida com o uso de uma resina experimental com fotoiniciador TPO. As unidades de fotopolimerização de terceira geração apresentaram maior potencial de polimerização independentemente do fotoiniciador. (AU)


Assuntos
Cura Luminosa de Adesivos Dentários , Luzes de Cura Dentária , Fotoiniciadores Dentários
4.
RGO (Porto Alegre) ; 67: e20190031, 2019. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1012906

RESUMO

ABSTRACT Objective: This study aimed to assess the bond strength and marginal microleakage in composite resin restorations, using the Single Bond Universal adhesive system associated with Ultralux (halogen) and Bluephase (LED) light curing units. Methods: For bond strength, 80 healthy human third molars were divided into halogen light (n=40) and LED (n=40), and subdivided according to the following application techniques for the adhesive system: etch-and-rinse (enamel), self-etching (enamel), etch-and-rinse (dentin), and self-etching (dentin). The teeth were subjected to the microtensile test and the fracture pattern was observed under an optical microscope at 40X magnification; they were analyzed by ANOVA, and Fisher and Tukey's tests (5%). For the marginal microleakage test, 120 class II cavities were prepared in 60 healthy human third molars that were randomly divided into halogen light (n=30) and LED (n=30), and subdivided according to the following application techniques for the adhesive system: etch-and-rinse, selective etching, and self-etching. The teeth were thermocycled 2000 times (±5/55°C), stained in 5% basic fuchsin and sectioned for qualitative and quantitative assessments; they were analyzed by Kruskall-Wallis and Dunn tests (5%). Results: For the bond strength of enamel and dentin, the adhesive application with prior acid etching was better than self-etching (p<0.0001), regardless of the type of light curing unit (p<0.05). Etch-and-rinse showed the lowest microleakage values (p<0.0001). Conclusion: Etch-and-rinse obtained the best results relative to the other application techniques for the adhesive system in both tests, regardless of the type of light curing unit.


RESUMO Objetivo: Avaliar a resistência de união e microinfiltração marginal em restaurações de resina composta, utilizando sistema adesivo Single Bond Universal associado com fotoativadores Ultralux (halógeno) e Bluephase (LED). Métodos: Para resistência de união, oitenta terceiros molares humanos hígidos foram divididos: Halógena (n=40); LED (n=40), sendo subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total-esmalte; autocondicionante-esmalte; condicionamento total-dentina; autocondicionante-dentina. Os dentes foram submetidos ao teste de microtração e o padrão de fratura foi observado em microscópio ótico - 40X de aumento, analisadas pelos testes ANOVA, Tukey e Fisher (5%). Para o ensaio de microinfiltração marginal, 120 cavidades classe II foram preparadas em sessenta terceiros molares humanos hígidos, aleatoriamente divididos: Halógena (n=30); LED (n=30) e subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total; condicionamento seletivo; autocondicionante. Os dentes foram termociclados 2000 vezes (±5/55ºC), corados em fucsina básica 5% e seccionados para avaliações qualitativa e quantitativa, analisados pelos testes Kruskall-Wallis e Dunn (5%). Resultados: Para resistência de união em esmalte e dentina, a aplicação do adesivo com condicionamento ácido prévio, foi melhor que o autocondicionante (p<0.0001), independentemente do tipo de fotoativador utilizado (p<0.05). O condicionamento total mostrou os menores valores de microinfiltração, (p<0.0001). Conclusão: O condicionamento total, obteve os melhores resultados em relação às outras técnicas de aplicação do sistema adesivo em ambos os testes, independentemente do tipo de aparelho fotoativador.

5.
Full dent. sci ; 10(38): 112-122, 2019.
Artigo em Português | BBO - Odontologia | ID: biblio-996561

RESUMO

O objetivo desta pesquisa foi avaliar a resistência da união, pelo método depush out, de pinos de fibra de vidro cimentados com cimento resinoso dual associado ao sistema adesivo Single Bond Universal, através de diferentes estratégias adesivas. Em 40 incisivos bovinos, um pino de fibra de vidro (Whitepost DC nº3) foi cimentado com cimento resinoso dual (RelyX ARC) e adesivo (Single Bond Universal). Os dentes foram divididos em 4 grupos (n = 10), de acordo com a estratégia de união. No Grupo 1 não se realizou nenhum tratamento do substrato dentinário. O Grupo 2 recebeu condicionamento com ácido fosfórico 37%. O Grupo 3 recebeu a aplicação de clorexidina 2% e o Grupo 4 recebeu condicionamento com ácido fosfórico 37% e aplicação da clorexidina 2%. Os grupos foram fatiados (1,8 mm) em três porções (cervical, média e apical) e tiveram seus pinos deslocados pela máquina universal de ensaios mecânicos. A análise estatística foi feita pelos testes ANOVA e Post Hoc de Tukey (p = 0,05). A técnica autocondicionante obteve maiores valores em MPa, mostrando a não necessidade de condicionamento ácido para melhoria da resistência adesiva. Para a técnica com condicionamento ácido, com e sem clorexidina, os valores de resistência adesiva foram estatisticamente semelhantes nos três terços radiculares. Para a técnica autocondicionante, com e sem o uso da clorexidina, a região cervical exibiu os maiores valores de resistência adesiva. Em ambas as técnicas, convencional e autocondicionante, não houve diferença significativa nos valores imediatos de resistência adesiva ao uso da clorexidina (AU).


The aim of this research was to evaluate by the push up method the bonding strength of fiberglass pins cemented with dual resin cement associated to the Single Bond Universal adhesive system through different adhesive strategies. In 40 bovine incisors, a fiberglass pin (Whitepost DC nº3) was cemented with dual resin cement (RelyX ARC) and adhesive (Single Bond Universal). The teeth were divided in 4 groups (n = 10), according to the union strategy. In Group 1, no treatment of the dentin substrate was performed. Group 2 received conditioning with 37% phosphoric acid. Group 3 received 2% chlorhexidine and Group 4 received conditioning with 37% phosphoric acid and 2% chlorhexidine application. The groups were sliced (1.8 mm) in three portions (cervical, middle, and apical) and had their pins displaced by the universal machine of mechanical tests. Statistical analysis was performed by ANOVA and Tukey's Post Hoc tests (p = 0.05). The self-etching technique obtained higher values in MPa, showing no need of acid conditioning to improve the adhesive strength. For the acid-conditioning technique with and without chlorhexidine, adhesive strength values were statistically similar in the three-thirds root. For the self-etching technique with and without the use of chlorhexidine, the cervical region exhibited the highest values of adhesive strength. In both techniques, conventional and self-etching, there was no significant difference in the immediate values of adhesive resistance to the use of chlorhexidine (AU).


Assuntos
Animais , Bovinos , Tratamento do Canal Radicular/métodos , Resistência à Tração , Teste de Materiais/métodos , Adesivos Dentinários , Pinos Dentários , Brasil , Análise de Variância , Estatísticas não Paramétricas , Incisivo
6.
Ortho Sci., Orthod. sci. pract ; 11(41): 28-32, 2018. ilus, tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-882315

RESUMO

Este estudo avaliou o grau de conversão de uma resina composta utilizada em tratamentos restauradores, Filtek Z 250 - 3M ESPE (Z250), e duas resinas ortodônticas: Orthocem - FGM (OC) e Transbond XT - 3M Unitek (TB) por meio da espectroscopia no infravermelho por transformada de Fourier (FTIR). Para isto, foram confeccionados quinze corpos de prova fotopolimerizados para cada resina. As medidas de grau de conversão foram realizadas imediatamente após a confecção das amostras. Os espectros de absorção no infravermelho foram obtidos num espectrofotômetro Parkin Elmer do Brasil. Os resultados das amostras tiveram sua normalidade aferida por meio do teste Kolmogorov-Smirnov e analisadas pelo teste ANOVA um critério, que demonstrou haver diferença estatística entre os grupos (p<0,05). (AU)


This study evaluated the degree of conversion of a composite resin used in restorative treatments, Filtek Z 250 - 3M ESPE (Z250), and two orthodontic resins: Orthocem - FGM (OC) and Transbond XT - 3M Unitek (TB) by means of infrared spectroscopy Fourier transform (FTIR). For this, fifteen bodies of light cured specimens were fabricated for each resin. Measures of degree of conversion were performed immediately after preparation of the samples. The infrared absorption spectra were obtained on a Parkin Elmer spectrophotometer Brazil. The results of the samples were measured using normality of the Kolmogorov-Smirnov test and analyzed by ANOVA criterion, which showed no statistical difference between groups (p<0,05). (AU)


Assuntos
Resinas Compostas , Cimentos Dentários , Cura Luminosa de Adesivos Dentários , Ortodontia
7.
Braz. dent. sci ; 20(4): 55-62, 2017. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-877943

RESUMO

Objectives: the aim of the present study was to evaluate the influence of adding different concentrations of chitosan to an experimental two-step etch-and-rinse adhesive system on the bond strength and failure mode to dentin. Material and Methods: thirty-two flat dentin surfaces were obtained from extracted human third molars and divided into four groups (n=8) for application of the adhesive systems: AD - conventional two-step adhesive system (Adper Single Bond 2); EXP ­ experimental two-step etch-and-rinse adhesive system; Chi0.2% - EXP with addition of 0.2% Chitosan; Chi0.5% - EXP with addition of 0.5% Chitosan. Resin composite build-ups were made and the composite/ dentin specimens were sectioned to obtain rectangular beams with a bond area of approximately 1mm2 . After 24 hours, the sticks were submitted to microtensile bond strength tests in a universal test machine. The fracture pattern was evaluated under a stereoscopic loupe at 40X magnification. Results: one-way analysis of variance showed that the type of adhesive system had no significant effect on the bond strength values (p = 0.142), showing the mean bond strength values (standard deviation), in MPa, for the groups as follows: AD=20.1 (5.4); EXP=16.6 (2.3); Chi0.2%=16.1 (2.8); Chi0.5%=16.9 (2.3). In all the groups there was predominance of cohesive fractures in dentin, representing 68 to 82% of the failure modes. Conclusion: the addition of 0.2 or 0.5% of chitosan had no influence on the bond strength and failure mode of an experimental two-step etch-andrinse adhesive system to dentin. (AU)


Objetivo: o objetivo deste estudo foi avaliar a influência da incorporação de diferentes concentrações de quitosana em um sistema adesivo experimental convencional de dois passos na resistência de união à dentina e modo de falha. Material e Métodos: trinta e duas superfícies de dentina planificadas foram obtidas de terceiros molares e separadas em quatro grupos (n=8) para aplicação dos sistemas adesivos: AD - sistema adesivo convencional de dois passos (Adper Single Bond 2); EXP ­ sistema adesivo convencional de dois passos experimental; Chi0,2% - EXP com incorporação de quitosana a 0,2%; Chi0,5% - EXP com incorporação de quitosana a 0,5%. Blocos de resina composta foram confeccionados e os espécimes de resina composte/ dentina foram seccionados para se obter palitos retangulares com interface adesiva foi seccionada para obtenção de palitos com área de união de aproximadamente 1mm2 . Após 24 horas, os palitos foram submetidos aos testes de resistência de união por microtração em máquina universal de ensaios. O modo de falha foi avaliada em lupa estereoscópica com aumento de 40 vezes. Resultados: análise de variância a um critério mostrou que o tipo de sistema adesivo não apresentou efeito significativo nos valores de resistência de união (p = 0,142), observando-se os respectivos valores de média (desvio-padrão), em MPa, para os grupos: AD=20,1 (5,4); EXP=16,6 (2,3); Chi0,2%=16,1 (2,8); Chi0,5%=16,9 (2,3). Para todos os grupos houve predominância de fraturas coesivas em dentina, representando 68 a 82% dos modos de falhas. Conclusão: a incorporação de quitosana a 0,2 ou 0,5% na influenciou a resistência de união à dentina e o modo de falha de um sistema adesivo convencional de dois passos experimental à dentina. (AU)


Assuntos
Quitosana , Cimentos Dentários , Análise do Modo e do Efeito de Falhas na Assistência à Saúde
8.
Braz. dent. sci ; 18(2): 103-108, 2015. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-766799

RESUMO

Objetivo: O objetivo desse estudo foi avaliar a resistência de união entre cimento de ionômero de vidro resina-modificado (CIVRM) e resina composta, considerando a utilização de sistemas adesivos de condicionamento acido total e autocondicionantes. Material e Métodos: Confeccionaram-se 60 blocos de CIVRM (Riva, SDI) de dimensões de 4x4 mm. Sobre os blocos, variou-se o protocolo de aplicação de diferentes sistemas adesivos (n = 10): Grupo 1 (Controle) – sem aplicação de adesivo; Grupo 2 – ácido fosfórico 37% + Single Bond; Grupo 3 - Single; Grupo 4 - Bond do Scotch Bond MultiPurpose Plus Adhesive; Grupo 5 - Clearfil SE Bond; Grupo 6: Obtibond All-in-One. Em seguida, foram confeccionados blocos de resina composta (Venus, Heraeus Kulzer) de dimensões de 4x4X4 mm. Foram realizados cortes nos espécimes para obtenção de amostras com área coesiva de 1 mm2, que foram submetidas ao teste de microtração em máquina de ensaios universal. Os dados foram submetidos aos testes ANOVA e Tukey. Resultados: ANOVA apresentou um valor de p < 0.05, o que indicou diferenças significantes entre os grupos (em Mpa): Grupo 2 – 32,83 a; Grupo 5 – 31,2 a; Grupo 3 – 25,15 ab; Grupo 6 – 22,92 ab; Grupo 4 22,15 ab; Grupo 1 – 13,84 b. Conclusão: os protocolos condicionamento ácido + Single Bond ou Clearfil SE Bond aumentaram resistência de união entre o CIVRM e a resina composta. A presença de uma camada de adesivo entre os dois materiais tende a melhorar a união entre CIVRM e resina composta.


Objective: The objective of this study was to evaluate the bond strength of resin-modified glass ionomer cement (RMGIC) to composite resin considering the use of conventional and self-etching adhesive systems. Material and Methods: 60 RMGIC blocks (Riva, SDI) measuring 4 x 4 x 4 mm. were constructed. On the blocks, the application of different protocols of adhesive systems (n = 10) was carried out: Group 1 (Control) - without application of adhesive agent; Group 2 - 37% phosphoric acid + conventional adhesive agent Single Bond 2; Group 3 - conventional adhesive agent Single Bond 2; Group 4 – conventional adhesive agent Scotch Bond Multi-Purpose; Group 5 - self-etching adhesive Clearfil SE Bond; Group 6: self-etching adhesive Optibond Allin-One. Next, resin composite blocks measuring 4 x 4 x 4 mm were constructed (Venus, Heraeus Kulzer). The specimens were cut to obtain sticks which were submitted to microtensile bond strength test in a universal testing machine. The data were submitted to ANOVA and Tukey test (5%). Results: ANOVA showed a value of p < 0.05, which indicated significant differences between the groups (in Mpa): Group 2 - 32.83; Group 5 - 31.2; Group 3 - 25,15b; Group 6 - 22.92; Group 4 - 22.15; Group 1 - 13.84. The analysis of fracture mode demonstrated that there was a predominance of adhesive and mixed fractures for all groups. Conclusion: The protocols of acid etching + conventional adhesive system Single Bond 2 (Group 2) or self-etching adhesive system Clearfil SE Bond (Group 5) increased the bond strength of RMGIC to the composite resin. The presence of an adhesive layer between the two materials tended to improve the bonding of RMGIC to composite resin


Assuntos
Resinas Compostas , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Resistência à Tração
9.
Braz. dent. sci ; 18(2): 58-64, 2015. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-766804

RESUMO

Objetivo: O objetivo desse estudo in vitro foi comparar a sorção (SO) e a solubilidade (SB) em água de sistemas adesivos e resinas compostas baseados em seus grupos funcionais dos monômeros. Material e Métodos: Três sistemas adesivos (Adper Single Bond 2 – 3M ESPE, Clearfil SE Bond – Kuraray, sistema adesivo da P90 – 3M ESPE) e três resinas compostas (Filtek Z350 – 3M ESPE, Filtek Z250 – 3M ESPE, Filtek P90 – 3M ESPE) foram testados. Oito espécimes de cada material foram preparados para avaliar a SO e SB. Inicialmente, os discos foram individualmente armazenados em um dessecador até a obtenção de uma massa constante e, em seguida, armazenados individualmente em água destilada até a massa se estabilizar novamente. Finalmente, os espécimes foram secos novamente no dessecador até uma massa constante ser obtida. SO e SB foram calculadas a partir dessas mensurações. Resultados: Os dados foram analisados pelo teste de ANOVA a 1 critério e teste de Tukey (p < 0,05). O adesivo do sistema P-90 apresentou os menores valores de SO e o Clearfil SE Bond apresentou os menores valores de SB. A resina composta Filtek P-90 apresentou os menores valores de SO e SB. Conclusão: Baseado nos resultados, pode-se concluir que a sorção e a solubilidade foram influenciadas pela composição dos materiais. O principal grupo funcional dos materiais determina a suscetibilidade à água e influencia o seu desempenho.


Objective: The objective of this in vitro study was to compare dentin bonding systems and composite resins based on their functional groups in terms of water sorption (WS) and water solubility (WSB). Material and Methods: Three dentin bonding systems (Adper Single Bond 2 – 3M ESPE, Clearfil SE Bond – Kuraray, P90 Adhesive System – 3M ESPE) and three commercial composite resins (Filtek Z350 – 3M ESPE, Filtek Z250 – 3M ESPE, Filtek P90 – 3M ESPE) were tested. Eight specimens of each material were prepared to evaluate the WS and WSB. The discs were individually stored in a desiccator until constant mass was achieved. Specimens were then individually stored in distilled water until the mass was stabilized again. Finally, the specimens were dried again in the desiccator until constant mass was obtained. WS and WSB were calculated from these measurements. Results: Data were analyzed by oneway ANOVA and Tukey post hoc test (p < 0.05). Filtek Silorane-Bond presented the lowest values of WS, and Clearfil SE Bond presented the lowest WSB. Filtek Silorane resin showed the lowest WS and WSB results. Conclusion: Based on the results, it can be concluded that the WS and WSB were influenced by the composition of the materials. The main functional group of the materials determines their susceptibility to water and influences their performance.


Assuntos
Resinas Compostas , Cimentos Dentários , Desintoxicação por Sorção , Solubilidade
10.
São José dos Campos; s.n; 2014. 93 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867590

RESUMO

O objetivo deste estudo foi avaliar a influência da viscosidade das resinas compostas e do tipo de cura dos sistemas adesivos, na resistência adesiva de resinas diretas submetidas a envelhecimento artificial. Foram utilizados 240 dentes incisivos bovinos, os quais tiveram a face vestibular desgastada para exposição da dentina. Os espécimes foram incluídos em resina acrílica autopolimerizável e a smear layer foi padronizada com lixa P600. Os espécimes foram divididos em 2 grupos de acordo com viscosidade da resina utilizada: Grupo GC: Grandio SO, alta viscosidade e Grupo GF: Grandio SO Heavy Flow, baixa viscosidade. Esses grupos foram subdivididos em 6 subgrupos de acordo com o sistema adesivo autocondicionante utilizado: FM: Futurabond M - fotopolimerizado, FDCQ: Futurabond Dual Cure Quimicamente ativado, FDCF: Futurabond Dual Cure Fotoativado, CS3: Clearfil S3 fotopolimerizado, CDCQ: Clearfil Dual Cure Quimicamente ativado e CDCF: Clearfil Dual Cure Fotoativado. Sobre a superfície dentinária foram construídos blocos de resina com auxílio de matriz de silicone. Os espécimes foram armazenados em água deionizada em estufa a 37 ºC, por um período de 24 h, e cada grupo foi subdividido em dois, sendo metade dos espécimes levados à cortadeira Labcut para obtenção de palitos dentina/resina medindo aproximadamente 1 X 1mm e a outra metade submetida a ciclagem termomecânica (300.000 ciclos mecânicos e 1000 ciclos térmicos) e sequencialmente cortados para obtenção de palitos. Os palitos foram submetidos a teste de microtração na máquina de ensaios universal DL-200MF (EMIC) e os resultados obtidos foram submetidos à análise estatística empregando-se os testes ANOVA 3 fatores e Tukey (α = 5%). O teste ANOVA mostra que houve diferença estatística somente para os fatores Adesivo (p = 0,0000) e Ciclagem termomecânica (p=0,0001), assim como para a interação entre eles (p = 0,0062). O teste de Tukey mostrou os seguintes resultados: Fator adesivo: CDCQ: 13,44 (± 5,13)a; FM: ...


The aim of this study was to evaluate the influence of composite resins viscosity and the type of cure of the adhesive systems on the bond strength of direct composite resins submitted to artificial aging. Two hundred forty bovine incisors had the buccal dentin exposed by sandblasting papers and were included in acrylic resin. The smear layer was standardized by sandblasting papers (600 SiC, Fepa-P). The specimens were divided in 2 groups according to the viscosity of the composite resin used: Group GC: Composite Grandio SO, high viscosity and Group GF: Grandio SO Heavy Flow, low viscosity These groups were divided in 6 according to the self-etch adhesive used: FM: Futurabond M – light cured, FDCQ: Futurabond Dual Cure - chemical cured, FDCF: Futurabond Dual Cure - light cured, CS3: Clearfil S3 – light cured, CDCQ: Clearfil Dual Cure - chemical cured and CDCF: Clearfil Dual Cure - light cured. Resin blocks were build up on the dentin surface using a silicon mold. The specimens were stored in deionized water 37°C along 24 h and half of them were cut to obtain resin/dentin sticks (1X1mm) and the other half submitted to thermomechanical aging (300.000 mechanical cycles and 1000 thermal cycles) and lately cut to sticks. The dentin/resin sticks were submitted to microtensile bond strength test (μTBS) in Universal machine DL-200MF (EMIC) and the results were analysed by 3 way ANOVA and Tukey’s test (α=5%). ANOVA showed signifficant statistical difference to the parameters: Adhesive (p=0,0000) and Thermomechanical aging (p=0,0001), as well to their interaction (p=0,0062). Tukey’s test showed the results: Adhesive: CDCQ: 13,44 (±5,13)a; FM: 14,01 (±2,71)a; CDCF: 14,51 (±4,98)a; FDCQ: 18,66 (±7,13)b; CS3: 18,80 (±6,50)b; FDCF: 19,18 (±7,39)b; Thermomechanical aging: Aged: 14,99 (±6,32)a; Not aged: 17,87 (±5,97)b. The conclusions were: Composite resin viscosities and type of cure of the adhesives did not influence on the bond strength. Thermomechanical aging decreased ...


Assuntos
Humanos , Resinas Compostas , Dentina , Adesivos Dentinários , Resistência à Tração
11.
Braz. dent. sci ; 17(1): 39-44, 2014. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728107

RESUMO

Objective: The aim of this study was to detect the influence of application mode of cleansing agents, on enamel and dentin during the adhesion process of a one-step self-etching adhesive system. Materials & Methods: 24 human molars were sectioned into halves along the long axis for enamel and dentin tests. The cleansing agents used were 3% hydrogen peroxide (group HP), anionic detergent (group AD), and antiseptic solution (group AS). In the experiment, these agents were applied with (active) and without friction (passive) on enamel and dentin surfaces. A one-step self-etching adhesive system (Clearfil S3 Bond) was applied on dental surface and composite resin cylinders were built using Tygon tubing molds. After 24 h, μSBS (microshear) test (1 mm/ min) and fracture analysis were performed. Results: There was no statistically significant difference in bond strength values regarding the application mode of cleansing agents for enamel and dentin (p ≥ 0.05). The use of antiseptic solution on enamel resulted in bond strength results significantly higher when compared with HP and AD (p = 0.014). Conclusions: Regarding bond strength to enamel and dentin using one-step self-etching adhesive system, application mode of the cleansing agents used in this study presented the same behavior. Antiseptic solution applied on enamel before the application of a one-step adhesive system increased bond strength performance


Objetivo: O objetivo deste estudo foi detectar a influência do modo de aplicação de agentes de limpeza, em esmalte e dentina durante o processo de adesão de um sistema adesivo auto-condicionante de passo único. Materiais e Métodos: 24 molares humanos foram seccionados em duas metades ao longo do eixo para testes de esmalte e dentina. Os agentes de limpeza utilizados foram: peróxido de hidrogênio 3% (grupo HP), detergente aniônico (grupo AD) e solução anti-séptica (grupo AS). No experimento, esses agentes foram aplicados com fricção (ativa) e sem fricção (passiva) em superfícies de esmalte e dentina. O sistema adesivo autocondicionante de um passo (Clearfil S3 Bond) foi aplicado na superfície dental e cilindros de resina composta foram construídas usando moldes (Tubos Tygon). Após 24 h, o teste de microcisalhamento (1 mm / min) e análise de fratura foram executados. Resultados: Não houve diferença estatisticamente significante nos valores de resistência de união em relação ao modo de aplicação de agentes de limpeza para esmalte e dentina (p ≥ 0,05). O uso de solução anti-séptica no esmalte resultou em resultados de resistência de união significativamente maior quando comparada com HP e AD (p = 0,014). Conclusões: Em relação à resistência de união ao esmalte e dentina utilizando sistema adesivo autocondicionante de passo único, o modo de aplicação dos agentes de limpeza utilizados neste estudo apresentaram o mesmo comportamento. A aplicação da solução anti-séptica aplicada sobre o esmalte antes da aplicação de um sistema adesivo de passo único apresentou melhor desempenho de resistência de união.


Assuntos
Humanos , Cimentos Dentários , Peróxido de Hidrogênio
12.
São José dos Campos; s.n; 2014. 93 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-870186

RESUMO

O objetivo deste estudo foi avaliar a influência da viscosidade das resinas compostas e do tipo de cura dos sistemas adesivos, na resistência adesiva de resinas diretas submetidas a envelhecimento artificial. Foram utilizados 240 dentes incisivos bovinos, os quais tiveram a face vestibular desgastada para exposição da dentina. Os espécimes foram incluídos em resina acrílica autopolimerizável e a smear layer foi padronizada com lixa P600. Os espécimes foram divididos em 2 grupos de acordo com viscosidade da resina utilizada: Grupo GC: Grandio SO, alta viscosidade e Grupo GF: Grandio SO Heavy Flow, baixa viscosidade. Esses grupos foram subdivididos em 6 subgrupos de acordo com o sistema adesivo autocondicionante utilizado: FM: Futurabond M - fotopolimerizado, FDCQ: Futurabond Dual Cure Quimicamente ativado, FDCF: Futurabond Dual Cure Fotoativado, CS3: Clearfil S3 fotopolimerizado, CDCQ: Clearfil Dual Cure Quimicamente ativado e CDCF: Clearfil Dual Cure Fotoativado. Sobre a superfície dentinária foram construídos blocos de resina com auxílio de matriz de silicone. Os espécimes foram armazenados em água deionizada em estufa a 37 ºC, por um período de 24 h, e cada grupo foi subdividido em dois, sendo metade dos espécimes levados à cortadeira Labcut para obtenção de palitos dentina/resina medindo aproximadamente 1 X 1mm e a outra metade submetida a ciclagem termomecânica (300.000 ciclos mecânicos e 1000 ciclos térmicos) e sequencialmente cortados para obtenção de palitos. Os palitos foram submetidos a teste de microtração na máquina de ensaios universal DL-200MF (EMIC) e os resultados obtidos foram submetidos à análise estatística empregando-se os testes ANOVA 3 fatores e Tukey (α = 5%). O teste ANOVA mostra que houve diferença estatística somente para os fatores Adesivo (p = 0,0000) e Ciclagem termomecânica (p=0,0001), assim como para a interação entre eles (p = 0,0062). O teste de Tukey mostrou os seguintes resultados: Fator adesivo: CDCQ: 13,44 (± 5,13)a; FM:...


The aim of this study was to evaluate the influence of composite resins viscosity and the type of cure of the adhesive systems on the bond strength of direct composite resins submitted to artificial aging. Two hundred forty bovine incisors had the buccal dentin exposed by sandblasting papers and were included in acrylic resin. The smear layer was standardized by sandblasting papers (600 SiC, Fepa-P). The specimens were divided in 2 groups according to the viscosity of the composite resin used: Group GC: Composite Grandio SO, high viscosity and Group GF: Grandio SO Heavy Flow, low viscosity These groups were divided in 6 according to the self-etch adhesive used: FM: Futurabond M – light cured, FDCQ: Futurabond Dual Cure - chemical cured, FDCF: Futurabond Dual Cure - light cured, CS3: Clearfil S3 – light cured, CDCQ: Clearfil Dual Cure - chemical cured and CDCF: Clearfil Dual Cure - light cured. Resin blocks were build up on the dentin surface using a silicon mold. The specimens were stored in deionized water 37°C along 24 h and half of them were cut to obtain resin/dentin sticks (1X1mm) and the other half submitted to thermomechanical aging (300.000 mechanical cycles and 1000 thermal cycles) and lately cut to sticks. The dentin/resin sticks were submitted to microtensile bond strength test (μTBS) in Universal machine DL-200MF (EMIC) and the results were analysed by 3 way ANOVA and Tukey’s test (α=5%). ANOVA showed signifficant statistical difference to the parameters: Adhesive (p=0,0000) and Thermomechanical aging (p=0,0001), as well to their interaction (p=0,0062). Tukey’s test showed the results: Adhesive: CDCQ: 13,44 (±5,13)a; FM: 14,01 (±2,71)a; CDCF: 14,51 (±4,98)a; FDCQ: 18,66 (±7,13)b; CS3: 18,80 (±6,50)b; FDCF: 19,18 (±7,39)b; Thermomechanical aging: Aged: 14,99 (±6,32)a; Not aged: 17,87 (±5,97)b. The conclusions were: Composite resin viscosities and type of cure of the adhesives did not influence on the bond strength. Thermomechanical aging decreased...


Assuntos
Humanos , Resinas Compostas , Dentina , Adesivos Dentinários , Resistência à Tração
13.
Dental press j. orthod. (Impr.) ; 18(6): 112-116, Nov.-Dec. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-697739

RESUMO

OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the low possibility of contamination during the process. METHODS: One hundred and twenty specimens were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used while in group 2 a led light-curing unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used while in subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. RESULTS: The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p > 0.05) and the ARI (p > 0.05) between the subgroups. CONCLUSION: The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requirements for bonding orthodontic accessories, and that the time for bonding was reduced to half, being necessary only one light exposure.


OBJETIVO: desenvolver uma nova ponteira para ser acoplada aos aparelhos fotopolimerizadores utilizados para colagem de braquetes e acessórios ortodônticos, e testar sua da efetividade em ensaio mecânico in vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos de refração e reflexão de luz. Apresenta como principal vantagem o menor tempo clínico durante o procedimento de colagem, reduzindo a possibilidade de contaminação durante o processo. MÉTODOS: por meio de ensaio de resistência ao cisalhamento e determinação do índice remanescente de adesivo (IRA), testou-se a ponteira desenvolvida em 120 corpos de prova. A amostra foi dividia em dois grupos. No grupo 1, foi utilizado aparelho fotopolimerizador de fonte de luz halógena e, no grupo 2, fonte de LED. Cada grupo foi subdividido. Nos subgrupos H1 e L1, utilizou-se a ponteira convencional. Nos subgrupos H2 e L2 a colagem foi feita utilizando a ponteira desenvolvida para a polimerização do material de colagem. RESULTADOS: os valores dos testes de cisalhamento e IRA para os subgrupos foram comparados entre si. Os resultados mostraram que não houve diferença estatisticamente significativa para o ensaio de resistência ao cisalhamento (p > 0,05) nem para o IRA (p > 0,05) entre os subgrupos. CONCLUSÃO: os testes de ensaio mecânico, assim como a análise do IRA, mostraram que a nova ponteira desenvolvida cumpriu os requisitos necessários à colagem dos acessórios ortodônticos, e que o tempo de colagem foi reduzido pela metade, sendo necessária uma só incidência.


Assuntos
Humanos , Luzes de Cura Dentária , Colagem Dentária/instrumentação , Cura Luminosa de Adesivos Dentários/instrumentação , Braquetes Ortodônticos , Adesividade , Luzes de Cura Dentária/classificação , Análise do Estresse Dentário/instrumentação , Desenho de Equipamento , Contaminação de Equipamentos/prevenção & controle , Teste de Materiais , Fibras Ópticas , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo
14.
Full dent. sci ; 4(14): 324-331, jan.-mar. 2013. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-681709

RESUMO

A escolha do agente de cimentação ideal para restaurações indiretas depende do material restaurador utilizado, das propriedades e características dos agentes cimentantes e do preparo dentário. Porém, a preferência profissional é um fator determinante na escolha. Este artigo descreve o passo a passo da cimentação de restauração indireta em resina composta para uso direto


The choice of ideal cementing agent for indirect restorations depends on the restorative material, the properties and characteristics of cementing agents and dental preparation. However, the professional preference is a determining factor in choice. This article describes the step by step cementation of indirect restoration with composite resin for direct use


Assuntos
Cimentos Dentários/química , Estética Dentária , Resinas Compostas/química
15.
Araraquara; s.n; 2013. 105 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867806

RESUMO

Objetivo: Avaliamos in vitro as variações da sensação de cor (∆E) e suas correlações após o clareamento de dentes submetidos à colagem e remoção de brackets ortodônticos, considerando: 1) o tempo de condicionamento ácido (15, 30 e 60 segundos); 2) os sistemas adesivos (TransbondTMXT, Opal Seal/Bond e TransbondTM Plus SEP) e 3) o momento em que o clareamento foi realizado em relação à presença de brackets (antes, durante ou depois), bem como o índice de adesivo remanescente (IAR) após descolagem dos brackets. Materiais e Métodos: Este trabalho foi subdividido em três artigos para abordar cada um dos objetivos propostos. A amostra foi composta de 270 pré-molares humanos, distribuídos aleatoriamente em 9 grupos: controle negativo (reprodutibilidade); controle positivo (apenas clareamento dentário); e 7 grupos experimentais. A determinação da cor dentária foi obtida pelo sistema CIELab, a partir de dados do espectrofotômetro, em avaliações da cor prévia ao clareamento e em 1, 15 e 30 dias após. Para verificar se existia diferença entre os grupos foi aplicada ANOVA a um fator, uma vez que o tamanho da amostra de cada grupo foi de n=30 (p < 0,05). E quando ANOVA indicou diferença, para identificar quais grupos diferiam entre si, foi aplicado o teste de comparações múltiplas de Tukey para variâncias homogêneas, identificadas pelo teste de Levene (p < 0,05). Resultados: O ∆E desde o préclareamento até 15 e 30 dias após foi estatisticamente diferente entre: o controle e o grupo com condicionamento ácido durando 15 segundos (p<0,05); o controle e os grupos colados com sistema adesivo TransbondTM XT e TransbondTM Plus SEP; assim como entre o grupo colado com Opal Seal/Bond e TransbondTM Plus SEP. Quanto ao momento em o clareamento foi realizado, apenas a variável IAR apresentou diferença estatisticamente significante nos valores médios, entre os três grupos experimentais (p < 0,05). Quanto às correlações, a variação de cor verificada 1 dia após o clareamento estava fortemente correlacionada com a de 15 dias após, assim como 15 com 30 dias após clareamento. Conclusões: O tempo de condicionamento ácido e os sistemas adesivos para colagem de brackets influenciaram o ∆E após clareamento. O momento em que o clareamento foi realizado não influenciou o ∆E, mas afetou o IAR, modificando a interface de fratura do adesivo durante a descolagem de brackets. E, a variação de cor obtida após 1 dia de clareamento estava correlacionada com a verificada após 15 e 30 dias


Objective: To evaluate in vitro the degree of color changes (∆E) and their correlations after bleaching tooth surfaces subjected to orthodontic brackets bonding and debonding, regarding: 1) the etching time (15, 30 and 60 seconds); 2) the adhesive system (TransbondTM XT, Opal Seal/Bond and TransbondTM Plus SEP); 3) the time point in which bleaching was performed (before, during and after bonding of brackets) and the adhesive remnant index (IAR) after bracket debonbing. Materials and Methods: This study was divided in three articles to address each of the proposed objectives. The sample consisted of 270 extracted premolars randomly divided in 9 groups: negative control (reproducibility); positive control (tooth bleaching only); and 7 experimental groups. The tooth color was determined by the CIELab system using the spectrophotometer data, in evaluations prior to bleaching and 1, 15 and 30 days after bleaching. To test whether there was difference between the groups one-way ANOVA was used, since the sample size of each group was n=30 (p<0,05). When ANOVA indicated a difference, in order to identify which groups differed from each other, we applied the multiple comparison test of Tukey for homogeneity of variances, identified by the Levene test (p < 0,05). Results: The ∆E from pre-bleaching up to 15 and 30 days after bleaching was statistically different between: control and etching time group of 15 seconds (p < 0,05); control and groups bonded withTransbondTM XT and TransbondTM Plus SEP bonding systems; as well as the group bonded with Opal Seal/Bond and TransbondTM Plus SEP. Regarding the time when the bleaching was performed, only the variable IAR presented statistically significant difference in the mean values among the three groups (p < 0,05). As for correlations, the color variation observed 1 day after bleaching was strongly correlated with 15 days after bleaching, as well as 15 to 30 days after bleaching. Conclusion: The etching time and the bonding systems influenced the ∆E after bleaching. The time point in which bleaching was performed did not influence the ∆E, but affected the IAR, modifying the interface of adhesive fracture during bracket debonding. In addition, the ∆E obtained 1 day after bleaching was correlated with those observed 15 and 30 days after bleaching


Assuntos
Humanos , Braquetes Ortodônticos , Cor , Cimentos Dentários , Clareamento Dental , Cura Luminosa de Adesivos Dentários , Ortodontia , Condicionamento Ácido do Dente , Dente Pré-Molar , Técnicas In Vitro , Análise de Variância , Adesivos Dentinários
16.
Araraquara; s.n; 2013. 82 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867774

RESUMO

IIntrodução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas pela broca multilaminada em baixa rotação. Conclusão: O TPSEP mostrou ser o modo de condicionamento de esmalte mais adequado para colagem de bráquetes; a não fotopolimerização do primer reduziu as resistências das colagens ao cisalhamento dos bráquetes metálicos, mas não as dos bráquetes cerâmicos; o tempo de execução do procedimento e o aspecto final da superfície do esmalte demonstraram que a broca multilaminada em baixa deve ser o método de escolha para remoção dos resíduos de adesivo


Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated that multi-blade carbide burr may be the method of choice to remove residual adhesive


Assuntos
Microscopia Eletrônica de Varredura , Análise de Elementos Finitos , Braquetes Ortodônticos , Cimentos Dentários , Cura Luminosa de Adesivos Dentários , Esmalte Dentário , Resistência ao Cisalhamento , Dente Pré-Molar , Dente Molar
17.
Pesqui. bras. odontopediatria clín. integr ; 12(3): 331-336, out. 2012. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874741

RESUMO

Objetivo: Avaliar "in vitro" a eficiência de adesivos autocondicionantes na microinfiltração marginal, variando o tempo de aplicação e o mecanismo de secagem. Método: Cavidades classe II foram preparadas em 80 molares humanos hígidos, divididos em quatro grupos: G1, Adper SE Plus (ASEP); G2, All Bond SE (ABSE); G3, Go! (GO); G4, Clearfil SE Bond (CSEB). Os adesivos foram utilizados variando o tempo de aplicação (recomendado pelo fabricante e duplicado) e o mecanismo de secagem (ar frio e quente). Após restaurados, os dentes foram armazenados em água destilada por 24h, termociclados, impermeabilizados, imersos em azul de metileno 2%, seccionados e avaliados quanto ao grau de microinfiltração de forma qualitativa, com lupa estereoscópica 40X por três examinadores calibrados. Utilizou-se a técnica estatística descritiva e inferencial (testes de Mann-Whitney e Kruskal-Wallis com aplicação de comparações pareadas do referido teste). Resultados: Observaram-se diferentes níveis de infiltração entre os adesivos em relação a forma de secagem e tempo de aplicação. A menor infiltração foi do ASEP com ar frio e tempo duplicado (média 11,05) e a maior foi do ABSE com ar frio e tempo de fabricante (média 30,50). Diferença entre os adesivos só não foi estatisticamente significante na associação ar quente e tempo do fabricante (p maior que 0,05). Analisando-se a forma de secagem e o tempo de aplicação, independentemente, o ASEP mostrou menor infiltração ao aplicar ar quente (24,73) e duplicar o tempo (22,55). Conclusão: A secagem com ar quente e a duplicação do tempo de aplicação do sistema adesivo mostrou-se ferramenta útil para melhorar a qualidade do selamento marginal em sistemas adesivos à base de água.


Objective: To evaluate "in vitro" the efficiency of self-etch adhesive systems on the marginal microleakage, varying the adhesive application time and the air drying mode. Method: Class II cavities were prepared in 80 sound human molars, divided into four groups: G1, Adper SE Plus (ASEP); G2, All Bond SE (ABSE); G3, Go! (GO); G4, Clearfil SE Bond (CSEB). The adhesive systems were used varying the application time (recommended by manufacturer or doubled) and the drying mode (cold air and hot air). The restored teeth were stored in distilled water for 24 h, subjected to a thermocycling regimen, rendered waterproof, immersed in 2% methylene blue, sectioned and examined as to the level of microleakage qualitatively with a 40x stereoscopic loupe by three calibrated examiners. Descriptive and inferential statistics were used for data analysis (Mann-Whitney and Kruskal-Wallis tests with paired comparisons). Results: There were different levels of microleakage among the adhesive systems regarding the drying mode and adhesive application time. The least leakage was obtained for ASEP with cold air drying and doubled adhesive application time (mean 11.05) and the greatest was obtained for ABSE with cold air drying and manufacturer's adhesive application time (mean 30.50). Difference among the adhesive systems was not statistically significant (p greater than 0.05) only for the combinations of hot air drying and manufacturer's recommended application time. Regarding the drying mode and the application time, independently, ASEP showed less leakage when drying was done with hot air (mean 24.73) and the adhesive application time was doubled (mean 22.55). Conclusion: Drying with hot air and doubling the adhesive application time were found to be effective in increasing the quality of the marginal seal in water-based adhesive systems.


Assuntos
Humanos , Cimentos Dentários , Infiltração Dentária/diagnóstico , Infiltração Dentária/etiologia , Materiais Dentários , Resinas Compostas , Interpretação Estatística de Dados , Técnicas In Vitro
18.
ROBRAC ; 21(58)jul.-set. 2012. tab
Artigo em Português | LILACS | ID: lil-676056

RESUMO

O objetivo desse estudo foi analisar a efetividade de sistemas adesivos convencionais e autocondicionantes, e de diferentes métodos de fotoativação para redução da microinfiltração marginal. Foram utilizados 48 dentes incisivos bovinos nesse estudo. Os dentes foram divididos em quatro grupos de 12 amostras de acordo com o tipo de adesivo ou método de fotoativação utilizado: Grupo 1- Sistema adesivo de passos fotoativadas por luz halógena com intensidade de 700 mW/cm2 Grupo 2 - Sistema adesivo de dois passos fotoativados pelo LED com intensidade de 470 mW/cm2; Grupo 3 - sistema adesivo autocondicionante fotoativados por luz halógena; Grupo 4 - Sistema adesivo autocondicionante fotoativados por LED. Uma resina composta nanoparticulada foi utilizada para restaurar todas as cavidades. Em seguida, os grupos foram submetidos ao tratamento de ciclagem térmica e foram colocados por 24 horas em solução de azul de metileno. A microinfiltração foi avaliada de acordo com o grau de penetração do corante na interface dente-restauração. Para análise estatística, foi utilizado o teste não paramétrico de Kruskal Wallis complementado pelo teste de Mann-Whitney, no nível de 5% de significância. O grupo 1 apresentou estatisticamente menores índices de microinfiltração marginal que o grupo 2 na parece oclusal (p<0.05) e os grupos 1 e 4 apresentaram menores graus de microinfiltração marginal que o grupo 2 na parede cervical(p<0.05). A aplicação do sistema adesivo de dois passos associado a polimerização com luz halógena promoveram os menores graus de microinfiltração marginal.


The aim of this research was to analyze the effectiveness of conventional and self-etching bonding systems and different curing methods for reduction of marginal microleakage. 48 bovine incisor teeth were used in this study. The teeth were divided into four groups of 12 samples according to the type of adhesive system or curing method used: Group 1- Two-step bonding system photoactivated by halogen light with intensity of 700 mW/cm2; Group 2- Two-step bonding system photoactivated by LED with 470 mW/ cm2 of intensity; Group 3 - Self etch bonding system photoactivated by halogen light; Group 4- Self etch bonding system photoactivated by LED. A nanofilled composite resin was used to restore all the cavities. Then the groups were subjected to thermal cycling treatment and were placed for 24 hours in a methylene blue solution. The microleakage was assessed according to the degree ofpenetration of the colorant in tooth-restoration interface. For statistical analysis, the non-parametric Kruskal Wallis test complemented by Mann-Whitney were used with 5 % level of significance. The Group 1 showed lower marginal microleakage than Group 2 on occlusal wall (p<0.05). Adittionally, appears and the groups 1 and 4 had smaller degrees of marginal microleakage that the cervical wall 2 Group (p<0.05). The application of two-step bonding system associated with the polymerization by halogen light promoted the lowest degrees of marginal microleakage.

19.
Rev. Odontol. Araçatuba (Impr.) ; 33(1): 28-31, jan.-jun. 2012. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-856926

RESUMO

Relato de caso clínico de paciente que apresentava como queixa principal a presença de restaurações manchadas na região anterior de seus dentes. Após meticulosas análises clínicas e discussões das condutas terapêuticas a serem adotadas, foi observado a presença de restaurações tipo classe IV nos dentes 11 e 21, em decorrência de uma fratura coronária oblíqua no passado. Porém o paciente não estava satisfeito com o resultado estético das mesmas, onde então foi planejado a realização da remoção das restaurações com ponta diamantada, para posteriormente ser utilizado materiais restauradores diretos para a correção da forma, função e estética dos dentes envolvidos na restauração. Como resultado final, observou-se que as resinas compostas foram capazes de devolver a forma, a função e a estética dental de maneira satisfatória, possibilitando o paciente à satisfação de sorrir novamente


A case report of a patient who presents as chief complaint presence of stained restorations in the anterior teeth. After analysis and discussion of the clinical therapeutic approaches to be adopted, it was observed the presence of type class IV restorations on teeth 11 and 21, due to an oblique coronal fracture in the past. But the patient was not satisfied with the aesthetic result, then where was planned the realization of the removal of the restorations, for subsequently be used direct restorative materials for the correction of form, function and esthetics. The final result showed that the restorations were able to return the form, function and aesthetic dental, thereby evidencing the proven development of restorative dentistry in the solution of aesthetic problems


Assuntos
Humanos , Feminino , Adulto Jovem , Adulto , Cimentos Dentários , Estética Dentária , Resinas Compostas , Restauração Dentária Permanente
20.
Rev. odonto ciênc ; 27(2): 143-146, 2012. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-649739

RESUMO

PURPOSE: To evaluate the shear bond strength of a self-etch adhesive and an etch-and-rinse adhesive when bonded to bovine enamel and dentin. METHODS: The labial surfaces of 28 bovine mandibular incisors were wet ground to achieve a flat enamel or dentin surface. A 1-step self-etch adhesive and a 3-step etch-and-rinse adhesive were bonded to enamel or dentin according to the manufacturer's instructions (Adper Easy One and Adper Scotchbond, respectively). A composite resin cylinder (Filtek Z350 XT) was built upon the adhesive layer using a silicon mold (2 mm in diameter × 3 mm high). The specimens were stored in 37°C distilled water for 24 h. The bond strength was measured by a universal testing machine at a crosshead speed of 1.0 mm/min. Student's t-test was used to compare bond strength values between adhesives at the 95% confidence level. RESULTS: For the enamel specimens, Adper Scotchbond had significantly higher values of bond strength than Adper Easy One (P=0.007). For the dentin specimens, there were no statistically significant differences between adhesives (P=0.12). CONCLUSION: Adper Easy One showed lower shear bond strength than Adper Scotchbond on enamel. For dentin, Adper Easy One showed bond strength similar to Adper Scotchbond.


OBJETIVO: Avaliar a resistência ao cisalhamento de adesivo autocondicionante e adesivo convencional ao esmalte e dentina bovinos. METODOLOGIA: As superfícies vestibulares de 28 incisivos mandibulares bovinos foram lixadas, sob refrigeração, para obtenção de superfícies de esmalte ou dentina planas. Um adesivo autocondicionante de passo único e um convencional de três passos foram utilizados de acordo com as instruções dos fabricantes (Adper Easy One and Adper Scotchbond, respectivamente). Um cilindro de resina composta foi confeccionado sobre a camada adesiva usando um molde de silicone (2 mm de diâmetro × 3 mm altura). Os espécimes foram armazenados a 37°C em água destilada por 24 h. A resistência de união foi mensurada através de máquina de ensaios universal à velocidade de 0.1 mm/min. Teste t de Student comparou os resultados de resistência de união entre os adesivos com nível de confiança de 95%. RESULTADOS: Para os espécimes de esmalte, Adper Scotchbond apresentou valores significativamente maiores que Adper Easy One (P=0.007). Para espécimes de dentina, não houve diferenças significativas entre os adesivos (P=0.12). CONCLUSÃO: Adper Easy One mostrou menor resistência ao cisalhamento do que Adper Scotchbond no esmalte. Para dentina, Adper Easy One mostrou resistência de união similar ao Adper Scotchbond.


Assuntos
Bovinos , Cimentos Dentários , Esmalte Dentário , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...